Agide Gimenez Marassi
Diffusion coefficient measurements for moving samples under strong magnetic field gradients
Among the numerous measurements carried out during a well-logging procedure, the Nuclear Magnetic Resonance (NMR) assessment is a fundamental analysis for determining the economic viability of a well for the oil industry. [1] Nowadays, two reliable approaches, Wireline Logging (WL) and Logging While Drilling (LWD), stand out. WL comprises the acquisition of NMR data under static conditions. On the other hand, in LWD, NMR measurements occur simultaneously with drilling, while the NMR tool experiences translation, rotation, and vibration relative to the rock formation. To better understand the NMR response acquired under LWD conditions, a setup emulating an LWD tool was developed, consisting of a single-sided magnet, radiofrequency probes, and a mechanical device that simulates relative sinusoidal motion between the sample and the applied magnetic field. [2] A bulk sample and three representative rocks, Fontainebleau Sandstone, Berea Sandstone, and Indiana Limestone, were investigated. Even though diffusion coefficient measurements are often neglected due to their inherent data-acquisition characteristics, the findings demonstrate that the diffusion coefficient of a fluid in a bulk sample or confined in a porous rock can be precisely measured and accurately predicted. [3] In strong magnetic field gradients, the Hahn spin echo is predominantly weighted by diffusion, an effect used to measure diffusion coefficients. Under LWD conditions, the diffusion coefficient measurement is significantly affected by signal phase modulation caused by sample movement in the presence of strong magnetic field gradients, making this measurement difficult. These results present solutions for accurate diffusion coefficient measurements by synchronizing Hahn spin-echo experiments with sample movement.
Acknowledgement/Funding: This study was financed by Petrobras, Brazil. Process Number 2020/00010-0
1) A. Gimenez Marassi, A. Gustavo de Araújo-Ferreira, E. Lucas-Oliveira, E. Luiz Géa Vidoto, A. Donizeti Fernandes de Amorim, W. Andrighetto Trevizan, T. José Bonagamba, Transverse relaxation measurements for moving samples in the presence of strong magnetic field gradients, Journal of Magnetic Resonance (2023) 107522. https://doi.org/10.1016/j.jmr.2023.107522.
2) E. Lucas-Oliveira, A.G. Marassi, A.G. Araújo-Ferreira, E.L.G. Vidoto, A.D.F. de Amorim, W.A. Trevizan, T.J. Bonagamba, Mechanically oscillating sample under magnetic field gradients: MOS-NMR, J. Magn. Reson. Open 12–13 (2022) 100084. https://doi.org/10.1016/j.jmro.2022.100084.
3) A.G. Marassi, A.G. de Araújo-Ferreira, E. Lucas-Oliveira, A.D.F. de Amorim, E.L.G. Vidoto, W.A. Trevizan, T.J. Bonagamba, Diffusion coefficient measurements for moving samples under strong magnetic field gradients, Journal of Magnetic Resonance 371 (2025) 107830. https://doi.org/10.1016/j.jmr.2025.107830.